50 OHM MODELS |
Model | Frequency Range (GHz) |
Attenuation Available (Any Value) |
Accuracy | VSWR | Input Power (Watts) |
Operating Temperature Range |
Connectors Male-Female Std. Config. |
RoHS Compliance |
||
DC - 2 GHz | 2 - 3 GHz | Continuous | Peak | |||||||
MA-50A/XB | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | BNC M/F | R |
MA-50A/XBF | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | BNC F/F | R |
MA-50A/XBM | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | BNC M/M | R |
MA-50A/XT | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | TNC M/F | R |
MA-50A/XTF | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | TNC F/F | R |
MA-50A/XTM | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | TNC M/M | R |
MA-50A/XS | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | SMA M/F | R |
MA-50A/XSF | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | SMA F/F | R |
MA-50A/XSM | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | SMA M/M | R |
MA-50A/XN | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | N M/F | R |
MA-50A/XNF | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | N F/F | R |
MA-50A/XNM | DC - 2.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | N M/M | R |
MA-50/XB | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | BNC M/F | R |
MA-50/XBF | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | BNC F/F | R |
MA-50/XBM | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | BNC M/M | R |
MA-50/XT | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | TNC M/F | R |
MA-50/XTF | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | TNC F/F | R |
MA-50/XTM | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | TNC M/M | R |
MA-50/XS | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | SMA M/F | R |
MA-50/XSF | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | SMA F/F | R |
MA-50/XSM | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | SMA M/M | R |
MA-50/XN | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | N M/F | R |
MA-50/XNF | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | N F/F | R |
MA-50/XNM | DC - 3.0 | 1 dB - 40 dB | ±0.8 dB | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | N M/M | R |
To specify the required attenuation value, replace the 'X' in the model with the attenuation value in dB. |
75 OHM MODELS |
Model | Frequency Range (GHz) |
Attenuation Available (Any Value) |
Accuracy Greater Of: |
VSWR | Input Power (Watts) |
Operating Temp. Range |
Connectors Male-Female Std. Config. |
RoHS Compliance |
||
DC - 2 GHz | 2 - 3 GHz | Continuous | Peak | |||||||
MA-75A/XB | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | BNC M/F | R |
MA-75A/XBF | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | BNC F/F | R |
MA-75A/XBM | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | BNC M/M | R |
MA-75A/XT | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | TNC M/F | R |
MA-75A/XTF | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | TNC F/F | R |
MA-75A/XTM | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | TNC M/M | R |
MA-75A/XN | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | N M/F | R |
MA-75A/XNF | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | N F/F | R |
MA-75A/XNM | DC - 2.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | -- | 2 | 1,000 | -55 to +125°C | N M/M | R |
MA-75B/XB | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | BNC M/F | R |
MA-75B/XBF | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | BNC F/F | R |
MA-75B/XBM | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | BNC M/M | R |
MA-75B/XT | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | TNC M/F | R |
MA-75B/XTF | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | TNC F/F | R |
MA-75B/XTM | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | TNC M/M | R |
MA-75B/XN | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | N M/F | R |
MA-75B/XNF | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | N F/F | R |
MA-75B/XNM | DC - 3.0 | 1 dB - 40 dB | ±0.5 dB or 5% | 1.20:1 | 1.30:1 | 2 | 1,000 | -55 to +125°C | N M/M | R |
To specify the required attenuation value, replace the 'X' in the model with the attenuation value in dB. |